Hello1 I'm trying to compile a long and wide horizontal table. I'm not sure if it fits the page. I tried many things but until now I haven't got any close result. Picture follow. I could really use some advices! The l and Y were chosen randomly…
\documentclass[a4paper,
12pt,
twoside,
BCOR10mm,
pagesize,
bibliography=totoc,
listof=totoc,
1.5headlines]{report} %{scrreprt}
\usepackage[left=3cm,right=3cm,top=3cm,bottom=3cm, bindingoffset=6mm]{geometry}
\setlength{\headheight}{14.49998pt}
\usepackage{graphicx} % Insert images
\usepackage[utf8]{inputenc}
\usepackage{caption}
\usepackage{subcaption}
\usepackage{float}
\usepackage[justification=centering]{caption}
\raggedbottom
\usepackage[T1]{fontenc}
\usepackage{xltabular} % for 'xltabular' environment
\usepackage{booktabs} % for well-spaced horizontal rules
\usepackage{amsmath}% for \smash[b] macro
\usepackage[skip=0.333\baselineskip]{caption}
\usepackage{ragged2e} % \Centering & \RaggedRight macros
\newcolumntype{Y}{>{\centering\arraybackslash}X} %
\newcolumntype{P}{>{\centering\arraybackslash}p{\hsize}} %
\newcolumntype{Z}{>{\raggedright\arraybackslash}X} %
\newcolumntype{Q}{>{\Centering}p{\hsize}}
\usepackage{adjustbox}
\usepackage[T1]{fontenc}
\usepackage{ragged2e}
\usepackage{rotating}
\usepackage[table]{xcolor}
\usepackage{booktabs, makecell, tabularx}
\usepackage{siunitx} % for S type columns
\begin{document}
\begin{adjustbox}{angle=90}
\begin{tabularx}{\textwidth}
{@{}llYYlllYYl@{}}
\toprule
market\_area\_1 & ag.unit & hydro. system &h Hydro\_plant\_name & hydro\_plant\_type & commissioning\_date & hydraulic\_head [m] & power\_turbine\_max [MW] & full\_load\_hours\_turbine & annual\_generation [GWh/a] & turbine\_type \\
\midrule
CHL1 & 0 & CONECTIVIDAD\_MAULE & HE\_LOS\_CONDORES & conventionalHydroStorage & 2023.0 & 480.00 &150.00 &3601.64 & 540.25 &peltonTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE &HE\_CIPRESES & conventionalHydroStorage & 1995.0 & 370.00 &105.82 &1814.46 & 192.01 &peltonTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_LA\_MINA & conventionalHydroStorage & 2018.0 &64.82 & 36.70 &1788.48 & 65.64 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_OJOS\_DE\_AGUA & conventionalHydroStorage & 2008.0 &65.96 &8.98 &4289.62 & 38.54 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_ISLA & conventionalHydroStorage & 1963.0 &92.11 & 69.00 &4719.75 & 325.66 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_CURILLINQUE & conventionalHydroStorage & 1993.0 & 114.86 & 91.77 &4227.24 & 387.93 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_LOMA\_ALTA & conventionalHydroStorage & 1997.0 &51.17 & 39.93 &4172.54 & 166.62 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_LOS\_HIERROS & conventionalHydroStorage & 2014.0 & 102.35 & 25.00 &3904.58 & 97.61 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_LOS\_HIERROS\_II & conventionalHydroStorage & 2015.0 &23.87 &6.00 &3085.52 & 18.51 & aggregatedTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_PEHUENCHE & conventionalHydroStorage & 1991.0 & 202.43 &568.29 &2110.01 &1199.10 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HE\_COLBUN & conventionalHydroStorage & 1985.0 & 171.43 &460.80 &2965.72 &1366.60 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_MACHICURA & conventionalHydroStorage & 1985.0 &37.53 & 94.76 &3152.45 & 298.73 & aggregatedTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_SAN\_IGNACIO & conventionalHydroStorage & 1996.0 &21.61 & 36.91 &3191.41 & 117.81 & aggregatedTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE &HP\_CHIBURGO & conventionalHydroStorage & 2007.0 & 110.33 & 19.16 &2767.31 & 53.01 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_MAULE & HP\_SAN\_CLEMENTE & conventionalHydroStorage & 2010.0 &36.84 &5.89 &2201.96 & 12.96 & aggregatedTurbine \\
CHL1 & 0 & CONECTIVIDAD\_LAJA & HE\_EL\_TORO & conventionalHydroStorage & 1973.0 & 616.00 &448.74 &1807.75 & 811.21 &peltonTurbine \\
CHL1 & 0 & CONECTIVIDAD\_LAJA & HP\_ABANICO & conventionalHydroStorage & 1948.0 & 136.47 & 92.71 &2332.72 & 216.27 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_LAJA & HE\_ANTUCO & conventionalHydroStorage & 1981.0 & 181.95 &319.17 &3237.69 &1033.37 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_LAJA &HP\_RUCUE & conventionalHydroStorage & 1998.0 & 145.56 &178.13 &3306.83 & 589.05 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_LAJA &HP\_QUILLECO & conventionalHydroStorage & 2007.0 &62.55 & 70.65 &3418.37 & 241.51 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_LAJA & HP\_LAJA\_I & conventionalHydroStorage & 2015.0 &15.58 & 34.06 &1779.08 & 60.59 & aggregatedTurbine \\
CHL1 & 0 & CONECTIVIDAD\_BIO\_BIO &HE\_RALCO & conventionalHydroStorage & 2004.0 & 181.41 &688.96 &2481.89 &1709.94 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_BIO\_BIO &HP\_PALMUCHO & conventionalHydroStorage & 2007.0 & 129.98 & 31.95 &6031.07 & 192.70 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_BIO\_BIO & HE\_PANGUE & conventionalHydroStorage & 1996.0 &90.98 &465.83 &2633.81 &1226.91 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_BIO\_BIO & HE\_ANGOSTURA & conventionalHydroStorage & 2014.0 &48.90 &321.00 &2802.40 & 899.57 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_ACONCAGUA &HP\_HORNITOS & conventionalHydroStorage & 2008.0 & 568.67 & 60.85 &2724.46 & 165.78 &peltonTurbine \\
CHL1 & 0 & CONECTIVIDAD\_ACONCAGUA & HP\_JUNCAL & conventionalHydroStorage & 1994.0 & 250.20 & 32.00 &7021.31 & 224.68 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_ACONCAGUA & HP\_BLANCO & conventionalHydroStorage & 1993.0 & 655.07 & 52.87 &2546.76 & 134.64 &peltonTurbine \\
CHL1 & 0 & CONECTIVIDAD\_ACONCAGUA &HP\_LOS\_QUILOS & conventionalHydroStorage & 1943.0 & 216.07 & 39.80 &4461.21 & 177.56 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_ACONCAGUA & HP\_CHACABUQUITO & conventionalHydroStorage & 2002.0 & 138.76 & 25.64 &3413.85 & 87.52 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_TINGUIRIRICA\_I &HP\_LA\_HIGUERA & conventionalHydroStorage & 2011.0 & 354.84 &154.61 &2939.04 & 454.41 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_TINGUIRIRICA\_II & HP\_LA\_CONFLUENCIA & conventionalHydroStorage & 2011.0 & 353.72 &162.79 &2000.48 & 325.66 & francisTurbine \\
CHL1 & 0 & CONECTIVIDAD\_PILMAIQUEN &HE\_PILMAIQUEN & conventionalHydroStorage & 1944.0 &30.70 & 40.68 &4716.68 & 191.86 & aggregatedTurbine \\
CHL1 & 0 & CONECTIVIDAD\_PILMAIQUEN &HP\_RUCATAYO & conventionalHydroStorage & 2012.0 &35.82 & 59.30 &3490.90 & 207.01 & aggregatedTurbine \\
CHL1 & 0 & CONECTIVIDAD\_RAPEL &HE\_RAPEL & conventionalHydroStorage & 1986.0 &70.49 &376.64 &1340.55 & 504.90 & francisTurbine \\
CHL1 & 0 &CANUTILAR &HE\_CANUTILLAR & conventionalHydroStorage & 1990.0 & 229.89 &171.57 &4066.02 & 697.61 & francisTurbine \\
CHL1 & 1 & SIC\_BIG & SIC\_AGGREGATED\_B\_run\_of\_river & runOfTheRiver & NaN & 1.00 & 1285.44 &2945.27 &3785.97 & aggregatedTurbine \\
CHL1 & 1 &SIC\_SMALL & SIC\_AGGREGATED\_S\_run\_of\_river & runOfTheRiver & NaN & 1.00 &511.61 &2945.27 &1506.84 & aggregatedTurbine \\
CHL0 & 1 & SING\_BIG & SING\_AGGREGATED\_B\_run\_of\_river & runOfTheRiver & NaN & 1.00 & 10.83 &2524.52 & 27.35 & aggregatedTurbine \\
CHL0 & 1 & SING\_SMALL & SING\_AGGREGATED\_S\_run\_of\_river & runOfTheRiver & NaN & 1.00 &6.55 &2524.52 & 16.54 & aggregatedTurbine \\
CHL2 & 1 &DECENTRAL &Decentral\_all\_run\_of\_river & runOfTheRiver & NaN & 1.00 & 24.08 &2524.52 & 60.80 & aggregatedTurbine \\
\bottomrule
\end{tabularx}
\end{adjustbox}
\end{document}
Best Answer
To long for the comment:
full\_load\_hours\_turbine
? Reconsider, thatfull load hours turbine
is more natural and readable, and also can be split in multi line cell,A possible solution with ugly result is to use of rotate cells headers:
which gives
You really need to reconsider to redesign your table. For example, split it in two tables, where remove fourth column from table and move their content to their table caption, and also consider afore comments.
Addendum: For completeness, let me added a case when table is split across two pages by use of the
xltabular
,\small