[Physics] Photon absorption probability for a given molecule in gas phase

quantum mechanicsspectroscopy

So I'm pretty sure I'm approaching this problem in the wrong way and I need some guidance (my first hint is that I think I'm thinking about a quantum mechanical problem too classically)

Suppose there is an isolated molecule in the gas phase with an average cross-sectional area to be exposed to radiation of $A$. (For my specific problem, the molecule is trapped in a superfluid Helium droplet, but I think the calculation should be roughly the same). If the radiation source has a flux $f$ (in units of photons/second/square area/0.1% BW) at energy $E$, what is the probability of the molecule absorbing a photon within a given interaction time $t$ if the absorption probability at a given energy is $P(E)$?

This is pretty easy to calculate if I treat the whole problem classically, i.e. like a ball and a target model. For some reason, though, I get numbers that seem to be way too low if I do this. I know it has to be more complicated than that, since light is a wave also. What am I missing?

I understand that transition probabilities are related to wavefunction overlap, etc. Also, I should note that the radiation in my specific problem is in the hard x-ray region, though I don't think that should change the answer.

Thanks in advance for your help.

Best Answer

the set of quantities you offered us to calculate the result is strange, or at least unusual. In particular, there is nothing such as the (dimensionless) absorption probability $P(E)$ for a molecule to absorb a photon.

The absorption probability is given by the cross section which you called $A$. For every process, one has to determine the cross section again. Usually, the cross section is called $\sigma$ instead of $A$.

So the best thing I could do with your numbers and functions would be to imagine that the cross section in your case was given by $\sigma(E) = P(E)\cdot A$. But it is really misleading to factorize the cross section in such ways. In particular, a universal "cross section area $A$" doesn't mean anything. Molecules are not hard balls that have a universal well-defined cross-sectional areas. They're nuclei surrounded by soft wave functions of electrons that reach arbitrarily far but are getting weaker with the distance - in fact, the (one) wave function for $N$ electrons lives in an $3N$-dimensional space rather than the ordinary $3$-dimensional space.

The number of events, in your case absorption events, is simply the product of the integrated luminosity and the cross section $\sigma$. The integrated luminosity is the time integral of luminosity $L$. It is normally written as $L=\rho\times v$ where $\rho$ is the number density of the beam - in particles per unit volume - and $v$ is the velocity - for photons, it's the speed of light $c$. The quantity $L$ happens to be the same thing as your flux $f$. If there are some losses or extra percentages etc., you have to be careful about it.

The quantities such as the cross section are designed in such a way that you are allowed to imagine that the molecule is classical and literally has the cross-sectional area $\sigma$ - that's why they were designed - and you get the right probability. If you do think right, you will indeed find out that only a small percentage of the X-ray photons is absorbed. That's why X-rays are being used to see through human bodies at X-ray pictures.

Best wishes Lubos