I see an inconsistency between the demo model and its description in the INFO block. In the motor model, the number of pole pairs is one; in the description, the number of poles is four (two pole pairs). When the number of pole pairs is greater than one, the rotor electrical position is different from the rotor mechanical position. This difference needs to be considered inside the controller block. The demo model should demonstrate operation more than one pole pair.
MATLAB: The documentation for the demo c2812pmsmsim is incorrect in Embedded Target for TI C2000 DSP 2.1PR (R2006b_prerelease)
Target Support Package TC2
Related Question
- Unable to run external simulation TI F28069M Matlab r2017a
- Is there support available for RTDX in Embedded Target for TI C2000 DSP 1.1.1 (R14SP1)
- How to create and open a Code Composer Studio(CCS) project for TI C2000 boards from Simulink in R2017a
- How to convert baud rate into sample time equivalent for the eCAN blocks in the Embedded Target for TI C2000 ™ DSP
- Does the “Data verification failed at address 0xxxxxx” error occur with Embedded Target for TI C2000 DSP 2.0 (R2006a)
- Does the C24x PWM block’s documentation refers to the “Pulse Width” setting when it should refer to the “Duty Cycle” setting in Embedded Target for TI C2000
Best Answer