Hi at all,
I got a littel problem while using S-Function, written in C. At the beginning of the simualtion I compute some initial values. I want to pass out one of them on an output port during the mdlOutput Routine. For that reason I use the
ssGetSimStatus
function an compare the result with the following expression:
SIMSTATUS_INITIALIZING
As the result the output port is Zero for all time, which is actually not the expected one. Changing the expression to
SIMSTAUTS_RUNNING
leads to the correct behavior, even during the initializing. (I figured this out with the help of fprintf function).
Does anybody know a way to set an output port to a specified value once at the initializing?
To help you understand my current implementation and problem, I post a snippet of my code, placed in the mdlOutput function:
// Set Schedule Value of the Rolling Force ssGetSimStatus(S, &SimStatus); if (SimStatus == SIMSTATUS_INITIALIZING) { Output[0] = DWorkVec[0]; #ifdef __EchoMode__ fprintf(LogFile, "\tSet Schedule Value of the Rolling Force\n"); #endif }
Thanks in advance, CN