This bug has been fixed in Release 14 Service Pack 3 (R14SP3). For previous product releases, read below for any possible workarounds:
We have verified that there is a bug in Simulink Verification and Validation 1.0 (R14) in the Requirements Management Interface. To work around this issue:
1. Determine the overall requirement count by right-clicking on the Signal
Builder block inside the Simulink diagram.
2. Look under the mask of the Signal Builder block and select the From-workspace block inside.
3. Type in the command prompt:
sbdata = get_param(gcb,'VnvData')
4. Look at the field value sbdata.groupReqCnt. This should be a vector with the length equal to the number of signal groups. The sum of the elements
should be the same as the total number of requirements.
5. Set the value to the correct distribution:
For example, if you have 13 requirements in the first signal group and 3 requirements in the second signal group, set:
sbdata.groupReqCnt = [13 3]
6. Apply the correct data structure to the model
set_param(gcb,'VnvData',sbdata)
7. Save the model and verify that the fix works.
Best Answer